Water Vapor Permeability Tester WVTR-920
Application

WVTR 220 is based on the infrared sensor method and available for the water
vapor permeability test of flexible films, sheeting and packages.
Films:
Plastic films, aluminum foil, aluminized films, plastic composite films, paper-
plastic composite films, coextruded films, aluminum foil composite films
Packages:
Plastic, rubber, paper, paper-plastic composite, glass and metal packages, e.g.
red wine bottles,blister, peanut oil packages, Tetra Pak materials,vacuum bags
Feather

(1) Electrolytic sensor method
(2) Own technology
(3) Film and package test
(4) 3 specimens test simultaneously and independently
(5) One-button test, test automatically in whole process
(6) Multiple test modes optional
(7) Data curves display
(8) omputer control
(9) Digital flow adjustment
(10) 3 Chambers with 3 temperature sensors
(11) Environment temperature and humidity sensor inside
(12) Chambers water bath technology
(13) Unit based on embedded system,24bit Δ-Σ AD
(14) Pressure, ppm water sensor and temperature overload protection
(15) Traceable reference film calibration
(16) Supports DSM system (DSM, lab data management system)
Principles

Film:
The specimen is clamped between the upper and lower chamber, the upper chamber is purged by a oxygen stream, and the other side of specimen, lower chamber is purged by a stream of nitrogen, due to the effect of oxygen concentration gradient at two sides of the specimen, oxygen molecules will permeate through the specimen into the nitrogen side, penetrated oxygen molecules will be carried to the coulometric sensor which generates the proportional signal, so oxygen transmission rate and permeability coefficient will be obtained by calculating the sensor signal.
Package:
The package is mounted on the lower chamber, the outside of the package is air or a pure oxygen stream, the inside of the package is purged by a nitrogen stream, oxygen will permeate through the wall into the inside of the package, penetrated oxygen molecules will be carried to the coulometric sensor which generates the proportional signal, so oxygen transmission rate will be obtained by calculating the sensor signal.
Configuration

Delivery: Main unit, computer, OX-TRANS software, tank regulator, PCIE card, communication cable, sample cutter, vacuum grease.
Optional: Temperature controller, package fixtures, reference film, vacuum grease, sample cutter, DSM system.
Main Technical Parameters

Technology   table
Test range Film:   0.001-52 g/m2·24h   (Standard)
     0.01-1100 g/m2·24h (Optional)
     
Resolution 0.001 g/m2·24h
Test range Package:
     0.0001~0.5 g/pkg·d
Resolution 0.00001g/pkg·d
Specimen   amount: 3 specimens,   independent
Temperature   range 5℃~95℃
Temperature   accuracy ±0.1℃
Humidity range 0%RH,35%RH-90%RH,100%RH
Humidity   accuracy ±1%RH
Sample size Film
     size :≥150mm*94mm;   thickness: ≤ 5mm
     Package
     max size: D120mm * 400mm
Test area 50cm2
Carrier gas 99.999% Nitrogen
carrier flow 0~200ml/min
Gas interface 1/8inch
Dimension 730mm(L) * 590mm(W) *   350mm(H)
Power supply AC 220V 50Hz
Net weight 56kg
Standards

ISO 15105-2, GB/T 19789,JIS K7126-B, YBB 00082003