GTR 736 is based on the differential pressure method, and is professionally applicable to the determination of gas transmission rate as well as solubility coefficient, diffusion coefficient and permeability coefficient of plastic films, laminated films, high barrier materials, sheeting, metal foils, rubber, tires and permeable membranes.
More+Applies to plastic films, sheets, rubber, laminated films, extrusion films, foils, paper, medical patches, release paper, non-woven fabrics etc testing of various items, such as tensile, break force, elastic modulus, elongation, seal strength, T-style peeling strength, 90 peeling strength, 180 peeling strength, widely used in food & pharmaceutical industries, quality inspection departments as well as research and development institutions.
More+For the determination of gross leaks in flexible packaging containing a headspace gas by bubble emission method.
More+Applies to plastic films, laminated films, extrusion films, foils, sheets, rubber, paper, paperboard, wood, brake pad, tyres, windshield wiper, conveyor belt, hare, l, carbon rod, catheter, artificial skin etc testing of static coefficient and dynamic coefficient, especially used in food & pharmaceutical industries, quality inspection departments as well as research and development institutions.
More+MENU
GTR 721 is based on the differential pressure method, and is professionally applicable to the determination of gas transmission rate as well as solubility coefficient, diffusion coefficient and permeability coefficient of plastic films, laminated films, high barrier materials, sheeting, metal foils, rubber, tires and permeable membranes.
GTR 721 is based on the differential pressure method, and is professionally applicable to the determination of gas transmission rate as well as solubility coefficient, diffusion coefficient and permeability coefficient of plastic films, laminated films, high barrier materials, sheeting, metal foils, rubber, tires and permeable membranes.
Vacuum differential pressure method
Built in embedded system with 24bit Δ-Σ AD, remote maintenance and upgrade
One-Click start a test and test automatically stop, no any manual operation is required during the process until the end of the test
Do NOT need to preset any test parameters before a test, zero operation experience requirements, proprietary technology
3 specimens test simultaneously and independently
According to the test state, the vacuum pump starts and stops automatically, do NOT need manual operation
Computer control, multiple test modes: Increment, proportional and intelligent
The temperatures of chambers which hollow inside and with circulating water are stable, high precision and wide range, 3 chambers with independent temperature sensors to monitor
Test under various RH conditions with Humidity generator (optional)
Built in environment temperature and humidity sensor
Permeability coefficient ,solubility coefficient and diffusion coefficient test
Various curves display: chambers temperature, test pressure, transmission rates, etc
Traceable reference film calibration
Supports DSM system (DSM, lab data management system)
Test range |
0.05 - 190,000 cm3/m2·24h·0.1MPa (Standard) |
Resolution |
0.001cm3/m2·24h·0.1MPa |
Samples |
3, independent |
Vacuum accuracy |
0.1Pa |
Temperature range |
5C - 95C |
Temperature accuracy |
±0.1C |
Humidity range |
0%RH,35%RH-90%RH,100%RH (optional) |
Humidity accuracy |
±1%RH (optional) |
Sample thickness |
less 3mm |
Sample size |
>= 150mm * 94mm |
Test area |
48cm2 |
Test gas |
O2, N2, CO2, He, etc |
Differential pressure |
-0.1MPa - 0.1MPa |
Gas interface |
Ф8mm |
Dimension |
730mm(L) * 510mm(W) * 350mm(H) |
Power supply |
AC 220V 50Hz |
Net wt |
63kg |
ASTM D1434, ISO 15105-1,ISO 2556,GB/T 1038-2000,JIS 7126-1,YBB 00082003
© 2012-2021 Systester Instruments Co., Ltd. - All copyright by Systester Instruments Co., Ltd.